Vestibule Lighting
TDG offers a wide variety of vestibule rail lighting fixture solutions. They can be single-function LED or fluorescent replacements. Also, they can incorporate a lens-mounted spotlight utilizing TDG’s revolutionary Capacitive Storage system for self-contained emergency lighting.
We offer:
- New LED or Fluorescent fixtures
- 24, 28.5, 37.5, 74, 110 vdc applications which are covered by a 20-95VDC & 50 – 130VDC operating range on LED installations or dedicated leading technology electronic DC Ballasts
- AC Versions available (110 – 220 VAC)
- Rectangular or Round versions
- Diffuser Technology lenses (for LED applications) or clear lenses
- Reverse polarity and transient spike protection
- 200,000-hr minimum continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
- 3-year warranty on the Lexekon Ballast product family
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
send an inquiry for this item
Related Products
-
Main Lighting Retrofit
Interior, Light RailWe offer:
- A Diffuser Technology lens which quickly snaps into an aluminum base, eliminates hot spots, and can be used behind existing lenses or advertising lenses
- An aluminum base that is easily installed, provides optimal thermal management, and can be quickly secured to existing fixture back liners
- 24, 28.5, 37.5 and 74vdc applications which are covered by a 10-95vdc operating range on LED installations.
- 110 – 240VAC systems in both LED and Fluorescent
- Reverse polarity and transient spike protection
- Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
- 10.5 – 18W power consumption on 48” unit depending on T12 or T8 replacement
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
-
Track Lights
Exterior, Light RailTrack lights on light rail vehicles (LRVs) illuminate the tracks directly in front.
We offer:
- Ruggedized polycarbonate lens (NFPA 130 compliant for flame, smoke, and toxicity requirements) which stands up to harsh traffic environments and daily car washes
- An internal LED mounting angle incorporated to eliminate blinding of oncoming drivers or pedestrians
- Custom sealed designs available
- A focused tight beam which illuminates tracks and switch points up to 50 feet in front of a light rail vehicle (LRV).
- Delphi Weather Pack connector as well as other sealed connectors upon request
- Availability as a drop-in replacement for standard round sealed beam lights
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
-
Number Board Lighting
Exterior, Light RailInstall new LED fixtures or versions to install replacement LED inserts into any existing incandescent or fluorescent enclosures.
We offer:
- 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
- Simple terminal block connections or cable assembly connections
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
-
Electronic Ballasts
Interior, Light RailLexekon is TDG’s sister division, through which you can source the finest modern electronic ballasts available for new builds, refurbishment projects, and maintenance replacement.
We offer:
- 24, 37.5, 74, 110 vdc versions in T5, T8, and T12 formats, and TDG’s Universal T8/T12 ballast which is unique in the industry!
- 120 – 220 VAC in T8 & T5 format
- Full-feature leading-edge technology, including
- Dimming capabilities
- “Auto-ON” and “Auto-OFF” labor-saving features
- End-Of-Life shutdown
- “Over Temp” and voltage protection
- Retrofit adapter plates which allow for simple drop-in replacement into existing vehicle mounting brackets
- Retrofit wiring harnessing for seamless integration with existing vehicle interconnect and wiring layouts
- Average lead-time of 6 to 8 weeks which is significantly shorter than our competitors
- 3-year warranty
The typical minimum order quantity is 25 pcs for most configurations.
All LEXEKON ballasts as part of a lighting system will meet or exceed these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
Stairwell Lighting