Red LED Night Vision Lighting
Sealed LED units can be supplied with either dedicated red LED inserts, or dual function units. The dual function units add a normal or white LED setting for general lighting needs.
We supply:
- 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
- Simple terminal block connections at rear
- A variety of flange & housing shapes
- Several finish and color choices
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
NFPA 130:2010 Flame Smoke and Toxicity Standards
send an inquiry for this item
Related Products
Reading Light
Interior, LocomotiveThe high-powered LED produces 300 LUX @ 36” with 360º adjustability. This ensures that
light is cast onto the work surface, not onto the windshield or side glass.We offer:
- 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
- Produces 379 lux at 36” and 300 Lux Intensity at 30”
- A dimmer control can be mounted on flange or remotely
- ‘Night Vision’ mode version available
- Several flange sizes or configurations
- Black powder-coated painted finish
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these safety standards:
- Will help locomotive meet 49 CFR 229.127 (b) requirements
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
LED Ladder Access Lighting
Exterior, LocomotiveThese high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.
We supply:
- Ruggedized polycarbonate lens (NFPA 130 compliant)
- 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
- Robust machined and sealed aluminum housing ready for painting or anodizing to natural or black
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- Will help locomotive meet 49 CFR 229.127 (b) requirements
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
PAR46 Marker Lights
Exterior, LocomotiveThis is a PAR46 drop-in replacement for sealed beam lights in both locomotive and cab car applications.
We offer:
- Ruggedized Polycarbonate Lens (NFPA 130 compliant)
- Reverse polarity and transient spike protection
- 20-95 vdc operation range
- Screw or ¼” disconnect terminations
- 25,000 hr minimum continuous operation
- Compliance with CFR 49 part 221
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- CFR 49 part 221 compliance (test report available upon request)
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
Task Lighting (Flood and Dome)
Interior, LocomotiveThis serves as a drop-in replacement for EMD pn 9096838 or MPI pn 1041198. The high-powered LED produces ~500 LUX @ 30” without casting light on windshield or side glass.
We offer:
20-95vdc operating range from the DC power supply through TDG’s Universal Driver
An illuminated switch or remote switch location options
White or black powder coated painted finishes
Reverse polarity and transient spike protection
100,000-hr minimum continuous operation for an LED system
24-month warranty on LED fixtures
All fixtures as a system meet or exceed these safety standards:APTA Normal Lighting Standard RP-E-012-99
APTA Emergency Lighting Standard SS-E-013-99 Rev 1
APTA Insulation Integrity Standard SS-E-001-98
APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
NFPA 130:2010 Flame Smoke and Toxicity Standards