Lighting Control Systems (ILCU and ELCU)
ILCU (Interior Lighting Control Unit)
All units as a system meet or exceed these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Emergency Lighting Design PR-E-S-013-99 Rev.1
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
- FRA 49 CFR Parts 238 and 239 Emergency Lighting
- APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
ELCU (Exterior Lighting Control Unit)
All units as a system meet or exceed these standards:
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
send an inquiry for this item
Related Products
-
Number Board Lighting
Exterior, Light RailInstall new LED fixtures or versions to install replacement LED inserts into any existing incandescent or fluorescent enclosures.
We offer:
- 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
- Simple terminal block connections or cable assembly connections
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
-
Main Lighting Retrofit
Interior, Light RailWe offer:
- A Diffuser Technology lens which quickly snaps into an aluminum base, eliminates hot spots, and can be used behind existing lenses or advertising lenses
- An aluminum base that is easily installed, provides optimal thermal management, and can be quickly secured to existing fixture back liners
- 24, 28.5, 37.5 and 74vdc applications which are covered by a 10-95vdc operating range on LED installations.
- 110 – 240VAC systems in both LED and Fluorescent
- Reverse polarity and transient spike protection
- Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
- 10.5 – 18W power consumption on 48” unit depending on T12 or T8 replacement
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
-
ADA Indicator Lighting
Interior, Light RailADA indicator lighting is built with TDG’S LED fixtures to provide superior light levels, power savings and reliability over traditional incandescent bulbs.
We offer:
- 24, 28.5, 37.5, 72, 110 vdc versions
- Tamperproof lens with stainless steel flange
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
-
Passive HPPL LLEPM Flooring System
Interior, Light RailThis passive high performance photoluminescent (HPPL) low location exit pathway marking (LLEPM) flooring system is fully repairable.
We supply:- An aluminum base that is easily installed, provides optimal thermal management, and can be quickly secured to existing fixture back liners
- 24, 28.5, 37.5 and 74vdc applications which are covered by a 10-95vdc operating range on LED installations.
- 110 – 240VAC systems in both LED and Fluorescent
- Reverse polarity and transient spike protection
- Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
- 10.5 – 18W power consumption on 48” unit depending on T12 or T8 replacement
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards