LED Stairway Lighting
Clients may choose not only a single function version, but also a dual version which adds emergency system functionality.
We offer:
- Several sizes and styles
- Ruggedized Polycarbonate Lenses (NFPA 130 compliant) which can be clear, translucent, or diffused
- A variety of bezel materials (such as aluminum and Kydex) in many colors and finishes
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these safety standards:
- Will help locomotive meet 49 CFR 229.127 (b) requirements
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
send an inquiry for this item
Related Products
Red LED Night Vision Lighting
Interior, LocomotiveSealed LED units can be supplied with either dedicated red LED inserts, or dual function units. The dual function units add a normal or white LED setting for general lighting needs.
We supply:
- 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
- Simple terminal block connections at rear
- A variety of flange & housing shapes
- Several finish and color choices
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
NFPA 130:2010 Flame Smoke and Toxicity Standards
PAR46 Marker Lights
Exterior, LocomotiveThis is a PAR46 drop-in replacement for sealed beam lights in both locomotive and cab car applications.
We offer:
- Ruggedized Polycarbonate Lens (NFPA 130 compliant)
- Reverse polarity and transient spike protection
- 20-95 vdc operation range
- Screw or ¼” disconnect terminations
- 25,000 hr minimum continuous operation
- Compliance with CFR 49 part 221
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- CFR 49 part 221 compliance (test report available upon request)
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
LED Ditch Lights
Exterior, LocomotiveLong-lasting LED components designed to withstand shock & vibration to provide years of maintenance-free service.
We offer:
- 75W of power used at maximum setting including lens heating element
- 30,000 hr service life
- Beam pattern meets FRA requirements
- Replacement for standard PAR56 sealed beam headlights and ditchlights
- Light recognizes low/medium/high settings used. on existing locomotives
- Integrated heating element prevents ice & snow to maintain unobstructed light output
All fixtures as a system meet or exceed these standards:
- FRA Certified
- Sealed to IP67
- CFR 49 Part 229.125 (a) (b) (d)
LED Cab Reading Lights
Interior, LocomotiveThe high-powered LED produces 300 LUX @ 36” with 360º adjustability. This ensures that
light is cast onto the work surface, not onto the windshield or side glass.We offer:
20-95vdc operating range from the DC power supply through TDG’s Universal Driver
A dimmer control version in which the dimmer can be placed remotely
Several flange sizes or configurations
Black powder-coated painted finish
Reverse polarity and transient spike protection
100,000-hr minimum continuous operation for an LED system
24-month warranty on LED fixtures
All fixtures as a system meet or exceed these safety standards:APTA Normal Lighting Standard RP-E-012-99
APTA Emergency Lighting Standard SS-E-013-99 Rev 1
APTA Insulation Integrity Standard SS-E-001-98
APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
NFPA 130:2010 Flame Smoke and Toxicity Standards