LED Number Board Lighting
Install new LED fixtures or replace LED inserts easily in existing incandescent or fluorescent enclosures.
We offer:
- 20-90vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
- Simple terminal block connections or cable assembly connections
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
send an inquiry for this item
Related Products
-
LED Platform/Ladder Access Lighting
Commuter Rail, ExteriorThese high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.
We supply:
- Ruggedized polycarbonate lens (NFPA 130 compliant)
- 20-90vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
- Robust machined and sealed aluminum housing ready for painting or anodizing to natural or black
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Insulation Integrity Standard SS-E-001-98
- 49CFR Part 38.81
- EN 13272
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
NFPA 130:2010 Flame Smoke and Toxicity Standards
-
Side Indicator Lighting
Commuter Rail, ExteriorLED side indicator lights come in a variety of styles and position numbers.
We offer:
A commuter rail version visible to a distance of ¼ mile which accommodates long train sets
Delphi Weather Pack connector as well as other sealed connectors upon request
Modular versions intended for adjacent custom configuration placements
Ruggedized machined solid aluminum housing ready for painting or for anodizing to natural or black
Standardized LED internal drivers and LED modules that enable final housing configurations to be easily customized
Ability for maintenance to be done from exterior or interior of the vehicle
Optional flush lens for improved cleaning of the lens surface during car washing
Reverse polarity and transient spike protection
100,000-hr minimum continuous operation for an LED system
24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:APTA Normal Lighting Standard RP-E-012-99
APTA Emergency Lighting Standard SS-E-013-99 Rev 1
APTA Insulation Integrity Standard SS-E-001-98
APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
NFPA 130:2010 Flame Smoke and Toxicity StandardsClick for diagramatic Exterior Red/Amber Indicator Lights spec sheet.
-
LED Spotlights
Commuter Rail, InteriorLED fixtures provide superior light levels, power savings and reliability over traditional incandescent bulbs.
We offer:
- 20-95vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
- AC Versions available (110 – 220 VAC)
- Several options for lenses
- A variety of flange and bezel finishes
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standard
-
CSU LED Emergency Lighting
Commuter Rail, InteriorCapacitive Storage –
With over 2000 Railcars and Locomotives in service or on order this APTA-compliant emergency lighting system uses capacitive power storage technology. It adapts easily to new builds or to existing rolling stock retrofits regardless of age.
We supply:
- Independent Capacitive Power Storage units which are able to power high-performance LED spotlights for up to 4 hours
- Ability to achieve full charge after a 15-minute charge period
- 50,000 – 500,000 mechanical charge cycles (depending on model)
- Superior replacement technology for traditional NiCad batteries
- Capacitors rated for 5 – 10 years of functional discharge service life (depending on Model & Environment)
- Single voltage 28.5, 37.5, 74, 110 vdc, or 120 / 240 vac versions available
- More than twice the light levels required by APTA throughout the 90-minute emergency interval
- An emergency lighting task load completely removed from existing car batteries
- Low-profile spotlights which are available in fixed or fully adjustable versions
- LED spotlight capability for simpler installation in existing or new fixture lenses
- Reverse polarity and transient spike protection
- 200,000-hr minimum continuous operation for an LED system due to purposefully under-driving high-efficiency LEDs
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed any combination of these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Emergency Lighting Design PR-E-S-013-99 Rev.1
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
- FRA 49 CFR Parts 238 and 239 Emergency Lighting