LED Interior Stairwell Lighting
Clients may choose not only a single function version, but also a dual version which adds emergency system functionality.
We offer:
- Several sizes and styles
- Available in most DC and AC voltage ranges
- Ruggedized Polycarbonate Lenses (NFPA 130 compliant) which can be clear, translucent, or diffused
- A variety of bezel materials (such as aluminum and Kydex) in many colors and finishes
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Insulation Integrity Standard SS-E-001-98
- 49 CFR Part 38.81
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
send an inquiry for this item
Related Products
Passive HPPL LLEPM Flooring System
Commuter Rail, InteriorThis passive high performance photoluminescent (HPPL) low location exit pathway marking (LLEPM) flooring system is fully repairable.
We supply:
- Rigid polycarbonate-based HPPL material
- A scuff-resistant surface
- Availability in 60-foot continuous lengths
- A mounting track offered in aluminum or color-matched polycarbonate
- 24-month warranty
The flooring system meets or exceeds these standards:
- APTA Standard for Low Location Exit Pathway Marking SS-PS-004-99 Rev 2
- NFPA 130:2010 Flame Smoke and Toxicity Standards for Rail
LED Retrofit Main Lighting
Commuter Rail, InteriorWe offer:
- A Diffuser Technology lens which quickly snaps into an aluminum base, eliminates hot spots, and can be used behind existing lenses or advertising lenses
- An aluminum base that is easily installed, provides optimal thermal management, and can be quickly secured to existing fixture back liners
- 24, 28.5, 37.5 and 74vdc applications which are covered by a 10-95vdc operating range on LED installations.
- 110 – 240VAC systems in both LED and Fluorescent
- Reverse polarity and transient spike protection
- Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
- 10.5 – 18W power consumption on 48” unit depending on T12 or T8 replacement
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
Organic LED (OLED) Lighting
Commuter Rail, InteriorTDG was amongst the first globally to offer OLED lighting to the rail industry. With panels as thin as 0.2mm and as light as 4.0g this is an ideal solution for weight reduction and power savings within either a rail car or locomotive.
With output approaching 140 lm / W as well as a CRI greater than 90 (@4000k) and the ability to offer a fully flexible panel OLEDs are rapidly approaching the levels of efficiency of conventional LEDs with more flexibility.All fixtures as a system will meet or exceed these safety standards:
• APTA Normal Lighting Standard RP-E-012-99
• APTA Emergency Lighting Standard SS-E-013-99 Rev 1
• APTA Insulation Integrity Standard SS-E-001-98
• APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
• NFPA 130:2010 Flame Smoke and Toxicity StandardsMain Lighting LED
Commuter Rail, InteriorThis main lighting solution for new builds adapts for ease of connection to TDG’s revolutionary Capacitive Storage system as well as ILCU and LCU based battery solutions for compliance to APTA-PR-E-S-013-99 Rev.1 (Formally APTA SS-E-013-99 Rev 1 ) “Standard for Emergency Lighting System Design for Passenger Rail Cars” & FRA 49 CFR Parts 238 and 239 Emergency Lighting Requirements.
We offer:
New LED or Fluorescent fixtures
- 24, 28.5, 37.5 and 74, 110 vdc applications which are covered by a 10 – 95vdc & 50 – 130 vdc operating range on LED installations or dedicated leading technology electronic DC Ballasts
- 110 – 240VAC systems in both LED and Fluorescent
- Diffuser Technology lenses (for LED applications) or clear and translucent lens options
- Reverse polarity and transient spike protection
- Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
- 3-year warranty on the Lexekon Ballast product family
- All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards