HPPL Emergency Signage
This passive high performance photoluminescent (HPPL) low location exit pathway marking (LLEPM) flooring system is fully repairable.
We supply:
- Rigid polycarbonate-based HPPL material
- A scuff-resistant surface
- Availability in 60-foot continuous lengths
- A mounting track offered in aluminum or color-matched polycarbonate
- 24-month warranty
The flooring system meets or exceeds these standards:
- APTA Standard for Low Location Exit Pathway Marking SS-PS-004-99 Rev 2
- APTA RT-S-VIM-022-08 “ Standard for Low-Location Emergency Path Marking for Rail Transit Vehicles”
- NFPA 130:2010 Flame Smoke and Toxicity Standards for Rail
- APTA RT-S-VIM-021-08 “Standard for Emergency Signage for Rail Transit Vehicles”
send an inquiry for this item
Related Products
Active LED LLEPM Flooring System
Interior, Light RailThis active LED low location exit pathway marking (LLEPM) flooring system is fully repairable. Also available in an Active / Passive Hybrid System.
We supply:
- Rigid polycarbonate system with LED light source
- A scuff-resistant surface
- Mounting within a polycarbonate-
or aluminum-based track designed to run the length of the railcar - 24-month warranty
The flooring system meets or exceeds these standards:
- APTA Standard for Low Location Exit Pathway Marking SS-PS-004-99 Rev 2, Section 6.1 “Electrically (Active) Powered Systems”
- NFPA 130:2010 Flame Smoke and Toxicity Standards for Rail
Emergency Lighting
Interior, Light RailCapacitive Storage –
With over 2000 Railcars and Locomotives in service or on order this APTA-compliant emergency lighting system uses capacitive power storage technology. It adapts easily to new builds or to existing rolling stock retrofits regardless of age.
We supply:
- Independent Capacitive Power Storage units which are able to power high-performance LED spotlights for up to 4 hours
- Ability to achieve full charge after a 15-minute charge period
- 50,000 – 500,000 mechanical charge cycles (depending on model)
- Superior replacement technology for traditional NiCad batteries
- Capacitors rated for 5 – 10 years of functional discharge service life (depending on Model & Environment)
- Single voltage 28.5, 37.5, 74, 110 vdc, or 120 / 240 vac versions available
- More than twice the light levels required by APTA throughout the 90-minute emergency interval
- An emergency lighting task load completely removed from existing car batteries
- Low-profile spotlights which are available in fixed or fully adjustable versions
- LED spotlight capability for simpler installation in existing or new fixture lenses
- Reverse polarity and transient spike protection
- 200,000-hr minimum continuous operation for an LED system due to purposefully under-driving high-efficiency LEDs
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed any combination of these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Emergency Lighting Design PR-E-S-013-99 Rev.1
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
- FRA 49 CFR Parts 238 and 239 Emergency Lighting
- APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
Lighting Control Systems (ILCU and ELCU)
Interior, Light RailILCU (Interior Lighting Control Unit)
All units as a system meet or exceed these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- APTA Emergency Lighting Design PR-E-S-013-99 Rev.1
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
- FRA 49 CFR Parts 238 and 239 Emergency Lighting
- APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
ELCU (Exterior Lighting Control Unit)
All units as a system meet or exceed these standards:
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards