End Door Lighting
LED fixtures provide superior light levels, power savings and reliability over traditional incandescent bulbs.
We offer:
- 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
- Several options for lenses
- A variety of flange and bezel finishes
- Reverse polarity and transient spike protection
- 100,000-hr minimum continuous operation for an LED system
- 24-month warranty on LED fixtures
All fixtures as a system meet or exceed these standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- EN 13272
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
send an inquiry for this item
Related Products
LED Retrofit Main Lighting
Commuter Rail, InteriorWe offer:
- A Diffuser Technology lens which quickly snaps into an aluminum base, eliminates hot spots, and can be used behind existing lenses or advertising lenses
- An aluminum base that is easily installed, provides optimal thermal management, and can be quickly secured to existing fixture back liners
- 24, 28.5, 37.5 and 74vdc applications which are covered by a 10-95vdc operating range on LED installations.
- 110 – 240VAC systems in both LED and Fluorescent
- Reverse polarity and transient spike protection
- Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
- 10.5 – 18W power consumption on 48” unit depending on T12 or T8 replacement
All fixtures as a system meet or exceed these safety standards:
- APTA Normal Lighting Standard RP-E-012-99
- APTA Emergency Lighting Standard SS-E-013-99 Rev 1
- EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
- APTA Insulation Integrity Standard SS-E-001-98
- APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
- NFPA 130:2010 Flame Smoke and Toxicity Standards
HPPL Emergency Pull Ring Housing
Commuter Rail, InteriorThe high performance photoluminescent (HPPL) material within this emergency pull ring housing is formulated based on the APTA definition of luminescence requirements.
We supply:
- Flexibility to be installed in new builds or retrofit applications
The HPPL in this pull ring housing was formulated to meet or exceed the Section 3.1.13 definition within these standards:
- APTA Standard for Low Location Exit Pathway Marking SS-PS-004-99 Rev 2, Section 3.1.13
- APTA Standard for Emergency Egress Access of Passenger Rail Equipment SS-PS-002-98 Rev 3, Section 3.1.13