View: 12 / 24 / ALL

  • Cabinet Lighting

    ,

    High-powered LEDs replace 100-watt incandescent bulbs, and consume a much lower 24 watts. This lighting is intended for placement within cabinets or other areas such as vestibule/entry or washroom areas. The translucent lens ensures comfortable light levels without any harsh glare.

    We supply:

    • Single voltage (37.5 or 74vdc) versions, or dual function 74vdc/120vac versions which switch input voltage operation automatically
    • Ruggedized polycarbonate lens (NFPA 130 compliant) or glass lenses
    • Aluminum housing ready for painting or for anodizing to natural or black
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Engine Room Lights

    ,

    This is available in single voltage (37.5 or 74vdc) and dual function 74vdc/120vac versions. The dual version automatically switches dependent on input voltage type.

    We supply:

    • High-powered LEDs which consume just 24 watts but provides output of a 100-watt incandescent bulb
    • Ruggedized glass lens with cage
    • 80°C ambient temperature operation
    • Black powder-coated painted finish as standard, and other finishes available
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Cab Reading Lights

    ,

    The high-powered LED produces 300 LUX @ 36” with 360º adjustability. This ensures that
    light is cast onto the work surface, not onto the windshield or side glass.

    We offer:

    20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    A dimmer control version in which the dimmer can be placed remotely
    Several flange sizes or configurations
    Black powder-coated painted finish
    Reverse polarity and transient spike protection
    100,000-hr minimum continuous operation for an LED system
    24-month warranty on LED fixtures
    All fixtures as a system meet or exceed these safety standards:

    APTA Normal Lighting Standard RP-E-012-99
    APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    APTA Insulation Integrity Standard SS-E-001-98
    APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    NFPA 130:2010 Flame Smoke and Toxicity Standards

  • LED Ditch Lights

    ,

    Long-lasting LED components designed to withstand shock & vibration to provide years of maintenance-free service.

    We offer:

    • 75W of power used at maximum setting including lens heating element
    • 30,000 hr service life
    • Beam pattern meets FRA requirements
    • Replacement for standard PAR56 sealed beam headlights and ditchlights
    • Light recognizes low/medium/high settings used. on existing locomotives
    • Integrated heating element prevents ice & snow to maintain unobstructed light output

    All fixtures as a system meet or exceed these standards:

    • FRA Certified
    • Sealed to IP67
    • CFR 49 Part 229.125 (a) (b) (d)
  • LED Ladder Access Lighting

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

    We supply:

    • Ruggedized polycarbonate lens (NFPA 130 compliant)
    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Robust machined and sealed aluminum housing ready for painting or anodizing to natural or black
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Number Board Lighting

    ,

    Install new LED fixtures or replace LED inserts easily in existing incandescent or fluorescent enclosures.

    We offer:

    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Simple terminal block connections or cable assembly connections
    • Various intensities available
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED PAR 56 Locomotive / Auxiliary Headlight

    ,

    Long-lasting LED components designed to withstand shock & vibration to provide years of maintenance-free service.

    We offer:

    • 75W of power used at maximum setting including lens heating element
    • Beam pattern meets FRA requirements
    • Replacement for standard PAR56 sealed beam headlights and ditchlights
    • Light recognizes low/medium/high or low/high settings used. on existing locomotives
    • Integrated heating element prevents ice & snow to maintain unobstructed light output
    • Can be designed to work with existing outage detectors
    • Engineered by JW SPEAKER

    All fixtures as a system meet or exceed these standards:

    • FRA Certified
    • Sealed to IP67
    • CFR 49 Part 229.125 (a) (b) (d)

    View Spec Sheet here

  • LED Stairway Lighting

    ,

    Clients may choose not only a single function version, but also a dual version which adds emergency system functionality.

    We offer:

    • Several sizes and styles
    • Ruggedized Polycarbonate Lenses (NFPA 130 compliant) which can be clear, translucent, or diffused
    • A variety of bezel materials (such as aluminum and Kydex) in many colors and finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these safety standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Main and Emergency Lights

    ,

    This high-powered LED for locomotives is a drop-in replacement for standard T12 fluorescent fixtures. It can also replace a 100-watt incandescent bulb, consuming just 24 watts in its place.

    We offer:

    • Optional self-contained Capacitive Storage Emergency Power system with 2 x 360º LED ‘Eyeball’ spotlights for a customizable 90 minutes of emergency lighting
    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Capacitors rated for 5 – 10 years of functional discharge service life (depending on Model & Environment)
    • Ruggedized polycarbonate lens (NFPA 130 compliant)
    • Black or Natural anodized finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • AAR S-580 Locomotive Crashworthiness Standard
    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • PAR46 Marker Lights

    ,

    This is a PAR46 drop-in replacement for sealed beam lights in both locomotive and cab car applications.

    We offer:

    • Ruggedized Polycarbonate Lens (NFPA 130 compliant)
    • Reverse polarity and transient spike protection
    • 20-95 vdc operation range
    • Screw or ¼” disconnect terminations
    • 25,000 hr minimum continuous operation
    • Compliance with CFR 49 part 221
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • CFR 49 part 221 compliance (test report available upon request)
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Reading Light

    ,

    The high-powered LED produces 300 LUX @ 36” with 360º adjustability. This ensures that
    light is cast onto the work surface, not onto the windshield or side glass.

    We offer:

    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Produces 379 lux at 36” and 300 Lux Intensity at 30”
    • A dimmer control can be mounted on flange or remotely
    • ‘Night Vision’ mode version available
    • Several flange sizes or configurations
    • Black powder-coated painted finish
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these safety standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards