View: 12 / 24 / ALL

  • Organic LED (OLED) Lighting

    ,

    TDG was amongst the first globally to offer OLED lighting to the rail industry. With panels as thin as 0.2mm and as light as 4.0g this is an ideal solution for weight reduction and power savings within either a rail car or locomotive.
    With output approaching 140 lm / W as well as a CRI greater than 90 (@4000k) and the ability to offer a fully flexible panel OLEDs are rapidly approaching the levels of efficiency of conventional LEDs with more flexibility.
    All fixtures as a system will meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Passive HPPL LLEPM Flooring System

    ,

    This passive high performance photoluminescent (HPPL) low location exit pathway marking (LLEPM) flooring system is fully repairable.
    We supply:

    • An aluminum base that is easily installed, provides optimal thermal management, and can be quickly secured to existing fixture back liners
    • 24, 28.5, 37.5 and 74vdc applications which are covered by a 10-95vdc operating range on LED installations.
    • 110 – 240VAC systems in both LED and Fluorescent
    • Reverse polarity and transient spike protection
    • Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
    • 10.5 – 18W power consumption on 48” unit depending on T12 or T8 replacement

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
    • EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Stairway Lighting

    ,

    Clients may choose not only a single function version, but also a dual version which adds emergency system functionality.

    We offer:

    • Several sizes and styles
    • Available in most DC and AC voltage ranges
    • Ruggedized Polycarbonate Lenses (NFPA 130 compliant) which can be clear, translucent, or diffused
    • A variety of bezel materials (such as aluminum and Kydex) in many colors and finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • 49 CFR Part 38.81
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Vestibule Lighting

    ,

    TDG offers a wide variety of vestibule rail lighting fixture solutions. They can be single-function LED or fluorescent replacements. Also, they can incorporate a lens-mounted spotlight utilizing TDG’s revolutionary Capacitive Storage system for self-contained emergency lighting.

    We offer:

    • New LED or Fluorescent fixtures
    • 24, 28.5, 37.5, 74, 110 vdc applications which are covered by a 20-95VDC & 50 – 130VDC operating range on LED installations or dedicated leading technology electronic DC Ballasts
    • AC Versions available (110 – 220 VAC)
    • Rectangular or Round versions
    • Diffuser Technology lenses (for LED applications) or clear lenses
    • Reverse polarity and transient spike protection
    • 200,000-hr minimum continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
    • 3-year warranty on the Lexekon Ballast product family

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards