View: 12 / 24 / ALL

  • Active LED LLEPM Flooring System

    ,

    This active LED low location exit pathway marking (LLEPM) flooring system is fully repairable. Also available in an Active / Passive Hybrid System.

    We supply:

    • Rigid polycarbonate system with LED light source
    • A scuff-resistant surface
    • Mounting within a polycarbonate-
      or aluminum-based track designed to run the length of the railcar
    • 24-month warranty

    The flooring system meets or exceeds these standards:

    • APTA Standard for Low Location Exit Pathway Marking SS-PS-004-99 Rev 2, Section 6.1 “Electrically (Active) Powered Systems”
    • NFPA 130:2010 Flame Smoke and Toxicity Standards for Rail
  • ADA Indicator Lighting

    ,

    ADA indicator lighting is built with TDG’S LED fixtures to provide superior light levels, power savings and reliability over traditional incandescent bulbs.

    We offer:

    • 24, 28.5, 37.5, 72, 110 vdc versions
    • Tamperproof lens with stainless steel flange
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards

     

  • Electronic Ballasts

    ,

    Lexekon is TDG’s sister division, through which you can source the finest modern electronic ballasts available for new builds, refurbishment projects, and maintenance replacement.

    We offer:

    • 24, 37.5, 74, 110 vdc versions in T5, T8, and T12 formats, and TDG’s Universal T8/T12 ballast which is unique in the industry!
    • 120 – 220 VAC in T8 & T5 format
    • Full-feature leading-edge technology, including
      • Dimming capabilities
      • “Auto-ON” and “Auto-OFF” labor-saving features
      • End-Of-Life shutdown
      • “Over Temp” and voltage protection
    • Retrofit adapter plates which allow for simple drop-in replacement into existing vehicle mounting brackets
    • Retrofit wiring harnessing for seamless integration with existing vehicle interconnect and wiring layouts
    • Average lead-time of 6 to 8 weeks which is significantly shorter than our competitors
    • 3-year warranty

    The typical minimum order quantity is 25 pcs for most configurations.

    All LEXEKON ballasts as part of a lighting system will meet or exceed these standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards

    Stairwell Lighting

  • Emergency Lighting

    ,

    Capacitive Storage –

    With over 2000 Railcars and Locomotives in service or on order this APTA-compliant emergency lighting system uses capacitive power storage technology. It adapts easily to new builds or to existing rolling stock retrofits regardless of age.

    We supply:

    • Independent Capacitive Power Storage units which are able to power high-performance LED spotlights for up to 4 hours
    • Ability to achieve full charge after a 15-minute charge period
    • 50,000 – 500,000 mechanical charge cycles (depending on model)
    • Superior replacement technology for traditional NiCad batteries
    • Capacitors rated for 5 – 10 years of functional discharge service life (depending on Model & Environment)
    • Single voltage 28.5, 37.5, 74, 110 vdc, or 120 / 240 vac versions available
    • More than twice the light levels required by APTA throughout the 90-minute emergency interval
    • An emergency lighting task load completely removed from existing car batteries
    • Low-profile spotlights which are available in fixed or fully adjustable versions
    • LED spotlight capability for simpler installation in existing or new fixture lenses
    • Reverse polarity and transient spike protection
    • 200,000-hr minimum continuous operation for an LED system due to purposefully under-driving high-efficiency LEDs
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed any combination of these standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Emergency Lighting Design PR-E-S-013-99 Rev.1
    • EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
    • FRA 49 CFR Parts 238 and 239 Emergency Lighting
    • APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”
  • HPPL Emergency Signage

    ,

    This passive high performance photoluminescent (HPPL) low location exit pathway marking (LLEPM) flooring system is fully repairable.

    We supply:

    • Rigid polycarbonate-based HPPL material
    • A scuff-resistant surface
    • Availability in 60-foot continuous lengths
    • A mounting track offered in aluminum or color-matched polycarbonate
    • 24-month warranty

    The flooring system meets or exceeds these standards:

    • APTA Standard for Low Location Exit Pathway Marking SS-PS-004-99 Rev 2
    • APTA RT-S-VIM-022-08 “ Standard for Low-Location Emergency Path Marking for Rail Transit Vehicles”
    • NFPA 130:2010 Flame Smoke and Toxicity Standards for Rail
    • APTA RT-S-VIM-021-08 “Standard for Emergency Signage for Rail Transit Vehicles”
  • LED Cab Console Lighting

    ,

    We offer:

    • Our LED version is rated to 100,000 hrs
    • 24, 28.5, 37.5 and 74, 110 vdc applications which are covered by a 10 – 95vdc & 50 – 130 vdc operating range on LED installations or dedicated leading technology electronic DC Ballasts
    • 110 – 240VAC systems in both LED and Fluorescent
    • Dual or Single versions available with or without high reliability push button switches
    • Fully adjustable
    • Tamperproof front bezel
    • Dimming available on LED units

    Reverse Polarity & Transient Spike protection
    Variety of flange/bezel finishes as well as lens options available

  • LED Headlights

    ,

    Long-lasting LED components designed to withstand shock & vibration to provide years of maintenance-free service;
    Designed by JW Speaker

    PAR 56 7″ Round 75V LED Locomotive Headlight/Auxiliary Light
    View Spec Sheet

    PAR 46 5.75″ LED Headlight
    View Spec Sheet

    PAR 56 7″ Round 8700-EV-12/24V Dot Headlamp w/H4 Black
    View Spec Sheet

    4″ x 6″ Rectangular LED 8800 12/24V Dot Hi/Lo LRV Headlamp
    View Spec Sheet

    5″ x 7″ Rectangular LED 8900 12/24V LED Dot Headlamp
    View Spec Sheet

  • LED Interior Step/ Threshold Lighing

    ,

    Clients may choose not only a single function version, but also a dual version which adds emergency system functionality.

    We offer:

    • Several sizes and styles
    • Available in most DC and AC voltage ranges
    • Ruggedized Polycarbonate Lenses (NFPA 130 compliant) which can be clear, translucent, or diffused
    • A variety of bezel materials (such as aluminum and Kydex) in many colors and finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • 49 CFR Part 38.81
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Marker and Brake Lights

    ,

    LED fixtures provide superior longevity, light levels, power savings and reliability over traditional incandescent bulbs.

    We offer:

    • Wide operating ranges provided by superior TDG constant current LED drivers such as 10-45vdc
    • Many existing lens shapes and colour options
    • Custom designs
    • A variety of flange and bezel finishes
    • Retrofit mounting bases for when the original bezel is no longer available, or will work with a retrofit installation
    • SAE/FMVSS/CMVSS 108 compliance
    • Sealed housings and also sealed connector solutions
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Side Indicator Lights

    ,

    LED side indicator lights come in a variety of styles and position numbers.

    We offer:

    • A light rail version visible to a distance of ¼ mile which accommodates long train sets
    • Delphi Weather Pack connector as well as other sealed connectors upon request
    • Modular versions intended for adjacent custom configuration placements
    • Ruggedized machined solid aluminum housing ready for painting or for anodizing to natural or black
    • Standardized LED internal drivers and LED modules that enable final housing configurations to be easily customized
    • Ability for maintenance to be done from exterior or interior of the vehicle
    • Optional flush lens for improved cleaning of the lens surface during car washing
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Spotlights

    ,

    LED fixtures provide superior light levels, power savings and reliability over traditional incandescent bulbs.

    We offer:

    • 20-95vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
    • AC Versions available (110 – 220 VAC)
    • Several options for lenses
    • A variety of flange and bezel finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standard