  • Lighting Control Systems

    ,

    ILCU (Interior Lighting Control Unit)

    All units as a system meet or exceed these standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Emergency Lighting Design PR-E-S-013-99 Rev.1
    • EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
    • FRA 49 CFR Parts 238 and 239 Emergency Lighting
    • APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”

     

     

  • Main Lighting for New Builds

    ,

    Main Lighting for New Builds

    This main lighting solution for new builds adapts for ease of connection to TDG’s revolutionary Capacitive Storage system as well as ILCU and LCU based battery solutions for compliance to APTA-PR-E-S-013-99 Rev.1 (Formally APTA SS-E-013-99 Rev 1 ) “Standard for Emergency Lighting System Design for Passenger Rail Cars” & FRA 49 CFR Parts 238 and 239 Emergency Lighting Requirements. As well as APTA RT-S-VIM-020-08 “Standard for Emergency Lighting System Design for Rail Transit Vehicles”

    We offer:

    New LED or Fluorescent fixtures

    • 24, 28.5, 37.5 and 74, 110 vdc applications which are covered by a 10 – 95vdc & 50 – 130 vdc operating range on LED installations or dedicated leading technology electronic DC Ballasts
    • 110 – 240VAC systems in both LED and Fluorescent
    • Diffuser Technology lenses (for LED applications) or clear and translucent lens options
    • Reverse polarity and transient spike protection
    • Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
    • 3-year warranty on the Lexekon Ballast product family
    • All fixtures as a system meet or exceed these safety standards:
    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Marker Lights

    ,

    LED fixtures provide superior longevity, light levels, power savings and reliability over traditional incandescent bulbs.

    We offer:

    • Wide operating ranges provided by superior TDG constant current LED drivers such as 10-45vdc
    • Many existing lens shapes and colour options
    • Custom designs
    • A variety of flange and bezel finishes
    • Retrofit mounting bases for when the original bezel is no longer available, or will work with a retrofit installation
    • SAE/FMVSS/CMVSS 108 compliance
    • Sealed housings and also sealed connector solutions
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Number Board Lighting

    ,

    Install new LED fixtures or versions to install replacement LED inserts into any existing incandescent or fluorescent enclosures.

    We offer:

    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Simple terminal block connections or cable assembly connections
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Organic LED (OLED) Lighting

    ,

    TDG was amongst the first globally to offer OLED lighting to the rail industry. With panels as thin as 0.2mm and as light as 4.0g this is an ideal solution for weight reduction and power savings within either a rail car or locomotive.

    With output approaching 140 lm / W as well as a CRI greater than 90 (@4000k) and the ability to offer a fully flexible panel OLEDs are rapidly approaching the levels of efficiency of conventional LEDs with more flexibility.

    All fixtures as a system will meet or exceed these safety standards:

    APTA Normal Lighting Standard RP-E-012-99
    APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    APTA Insulation Integrity Standard SS-E-001-98
    APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    NFPA 130:2010 Flame Smoke and Toxicity Standards

  • Passive HPPL LLEPM Flooring System

    ,

    This passive high performance photoluminescent (HPPL) low location exit pathway marking (LLEPM) flooring system is fully repairable.

    We supply:

    Rigid polycarbonate-based HPPL material
    A scuff-resistant surface
    Availability in 60-foot continuous lengths
    A mounting track offered in aluminum or color-matched polycarbonate
    24-month warranty

  • Platform Lights

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

    We supply:

    • Ruggedized polycarbonate lens (NFPA 130 compliant)
    • 20-90vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
    • Robust machined and sealed aluminum housing ready for painting or anodizing to natural or black
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • 49CFR Part 38.81
    • EN 13272
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Side Indicator Lighting

    ,

    LED side indicator lights come in a variety of styles and position numbers.

    We offer:

    • A light rail version visible to a distance of ¼ mile which accommodates long train sets
    • Delphi Weather Pack connector as well as other sealed connectors upon request
    • Modular versions intended for adjacent custom configuration placements
    • Ruggedized machined solid aluminum housing ready for painting or for anodizing to natural or black
    • Standardized LED internal drivers and LED modules that enable final housing configurations to be easily customized
    • Ability for maintenance to be done from exterior or interior of the vehicle
    • Optional flush lens for improved cleaning of the lens surface during car washing
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Track Lights

    ,

    Track lights on light rail vehicles (LRVs) illuminate the tracks directly in front.

    We offer:

    • Ruggedized polycarbonate lens (NFPA 130 compliant for flame, smoke, and toxicity requirements) which stands up to harsh traffic environments and daily car washes
    • An internal LED mounting angle incorporated to eliminate blinding of oncoming drivers or pedestrians
    • Custom sealed designs available
    • A focused tight beam which illuminates tracks and switch points up to 50 feet in front of a light rail vehicle (LRV).
    • Delphi Weather Pack connector as well as other sealed connectors upon request
    • Availability as a drop-in replacement for standard round sealed beam lights
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards