View: 12 / 24 / ALL

  • LED PAR46 Marker Light

    ,

    This is a PAR46 drop-in replacement for sealed beam lights in both locomotive and cab car applications.
    We offer:
    • Ruggedized Polycarbonate Lens (NFPA 130 compliant)
    • Reverse polarity and transient spike protection
    • Screw or ¼” disconnect terminations
    • 25,000 hr minimum continuous operation
    • Compliance with CFR 49 part 221
    • 24-month warranty on LED fixtures
    All fixtures as a system meet or exceed these standards:
    • CFR 49 part 221
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards

  • LED Platform Light II

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

  • LED Platform Lighting

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

  • LED Platform/Ladder Access Lighting

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

    We supply:

    • Ruggedized polycarbonate lens (NFPA 130 compliant)
    • 20-90vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
    • Robust machined and sealed aluminum housing ready for painting or anodizing to natural or black
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • 49CFR Part 38.81
    • EN 13272
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1

    NFPA 130:2010 Flame Smoke and Toxicity Standards

  • LED Reading Light

    ,

    TDG has supplied over 150,000 Reading Lights to the Commuter Rail industry over the past 10 years!

    We offer:

    • Available in LED or Halogen versions
    • Our LED version is rated to 80,000 hrs and our Halogen bulbs are rated to 5,000 hrs.
    • Available in a variety of operating voltages such as 28VDC/VAC and others up to 110VDC when powered by TDG’s Universal Driver
    • Dual or Single versions available with or without high reliability push button switches
    • Fully adjustable
    • Tamperproof front bezel
    • Dimming available on LED units

    Reverse Polarity & Transient Spike protection
    Variety of flange/bezel finishes as well as lens options available

  • LED Retrofit Main Lighting

    ,

    We offer:

    • A Diffuser Technology lens which quickly snaps into an aluminum base, eliminates hot spots, and can be used behind existing lenses or advertising lenses
    • An aluminum base that is easily installed, provides optimal thermal management, and can be quickly secured to existing fixture back liners
    • 24, 28.5, 37.5 and 74vdc applications which are covered by a 10-95vdc operating range on LED installations.
    • 110 – 240VAC systems in both LED and Fluorescent
    • Reverse polarity and transient spike protection
    • Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
    • 10.5 – 18W power consumption on 48” unit depending on T12 or T8 replacement

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Spotlights

    ,

    LED fixtures provide superior light levels, power savings and reliability over traditional incandescent bulbs.

    We offer:

    • 20-95vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
    • AC Versions available (110 – 220 VAC)
    • Several options for lenses
    • A variety of flange and bezel finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standard
  • LED Vestibule Lighting

    ,

    TDG offers a wide variety of vestibule rail lighting fixture solutions. They can be single-function LED or fluorescent replacements. Also, they can incorporate a lens-mounted spotlight utilizing TDG’s revolutionary Capacitive Storage system for self-contained emergency lighting.

    We offer:

    • New LED or Fluorescent fixtures
    • 24, 28.5, 37.5, 74, 110 vdc applications which are covered by a 20-95VDC & 50 – 130VDC operating range on LED installations or dedicated leading technology electronic DC Ballasts
    • AC Versions available (110 – 220 VAC)
    • Rectangular or Round versions
    • Diffuser Technology lenses (for LED applications) or clear lenses
    • Reverse polarity and transient spike protection
    • 200,000-hr minimum continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
    • 3-year warranty on the Lexekon Ballast product family

    All fixtures as a system meet or exceed these safety standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Lighting Control Systems

    ,
    • Available in 28.5VDC, 37.5VDC, 76VDC, 110VDC, and 120VAC (Custom Voltages Availables)
    • Firmware controlled lighting control
    • Can operate emergency lighting, dimming control, occupancy, color change, etc
    • Optional battery unit fully compliant with FRA 49 CFR Parts 238 and 239, APTA PR-E-S-013-99, Rev. 1, and APTA RT-VIM-S-020-10
    • Optional Ethernet or customized interface to control lighting levels/color across train set.
    • Option Wireless CommunicationAll Control Units can be designed as a system meet or exceed these safety standards:
      APTA Normal Lighting Standard RP-E-012-99
      GM/RC2531 – Recommendations for Rail Vehicle Emergency Lighting
      FRA 49 CFR Parts 238 and 239 “Passenger Train Emergency Systems II; Final Rule”
      EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
      APTA Emergency Lighting Standard SS-E-013-99 Rev 1
      APTA Insulation Integrity Standard SS-E-001-98
      APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
      IEEE SA – 1558-2004 Standard for Software Documentation for Rail Equipment and Systems
  • Main Lighting LED

    ,

    This main lighting solution for new builds adapts for ease of connection to TDG’s revolutionary Capacitive Storage system as well as ILCU and LCU based battery solutions for compliance to APTA-PR-E-S-013-99 Rev.1 (Formally APTA SS-E-013-99 Rev 1 ) “Standard for Emergency Lighting System Design for Passenger Rail Cars” & FRA 49 CFR Parts 238 and 239 Emergency Lighting Requirements.

    We offer:

    New LED or Fluorescent fixtures

    • 24, 28.5, 37.5 and 74, 110 vdc applications which are covered by a 10 – 95vdc & 50 – 130 vdc operating range on LED installations or dedicated leading technology electronic DC Ballasts
    • 110 – 240VAC systems in both LED and Fluorescent
    • Diffuser Technology lenses (for LED applications) or clear and translucent lens options
    • Reverse polarity and transient spike protection
    • Up to 200,000-hr continuous operation for an LED system, achieved by purposefully under-driving high-efficiency LEDs
    • 3-year warranty on the Lexekon Ballast product family
    • All fixtures as a system meet or exceed these safety standards:
    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • EN 13272 Railway Applications – Electrical Lighting for Rolling Stock in Public Transportation Systems
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Organic LED (OLED) Lighting

    ,

    TDG was amongst the first globally to offer OLED lighting to the rail industry. With panels as thin as 0.2mm and as light as 4.0g this is an ideal solution for weight reduction and power savings within either a rail car or locomotive.
    With output approaching 140 lm / W as well as a CRI greater than 90 (@4000k) and the ability to offer a fully flexible panel OLEDs are rapidly approaching the levels of efficiency of conventional LEDs with more flexibility.

    All fixtures as a system will meet or exceed these safety standards:
    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards

  • Passive HPPL LLEPM Flooring System

    ,

    This passive high performance photoluminescent (HPPL) low location exit pathway marking (LLEPM) flooring system is fully repairable.

    We supply:

    • Rigid polycarbonate-based HPPL material
    • A scuff-resistant surface
    • Availability in 60-foot continuous lengths
    • A mounting track offered in aluminum or color-matched polycarbonate
    • 24-month warranty

    The flooring system meets or exceeds these standards:

    • APTA Standard for Low Location Exit Pathway Marking SS-PS-004-99 Rev 2
    • NFPA 130:2010 Flame Smoke and Toxicity Standards for Rail