View: 12 / 24 / ALL

  • End Door Lighting

    ,

    LED fixtures provide superior light levels, power savings and reliability over traditional incandescent bulbs.

    We offer:

    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Several options for lenses
    • A variety of flange and bezel finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • EN 13272
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Number Board Lighting

    ,

    Install new LED fixtures or replace LED inserts easily in existing incandescent or fluorescent enclosures.

    We offer:

    • 20-90vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
    • Simple terminal block connections or cable assembly connections
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED PAR 56 Cab Car / Auxiliary Headlight

    ,

    Long-lasting LED components designed to withstand shock & vibration to provide years of maintenance-free service.

    We offer:

    • 75W of power used at maximum setting including lens heating element
    • Beam pattern meets FRA requirements
    • Replacement for standard PAR56 sealed beam headlights and ditchlights
    • Light recognizes low/medium/high or low/high settings used. on existing locomotives
    • Integrated heating element prevents ice & snow to maintain unobstructed light output
    • Can be designed to work with existing outage detectors
    • Engineered by JW SPEAKER

    All fixtures as a system meet or exceed these standards:

    • FRA Certified
    • Sealed to IP67
    • CFR 49 Part 229.125 (a) (b) (d)
  • LED PAR46 Marker Light

    ,

    This is a PAR46 drop-in replacement for sealed beam lights in both locomotive and cab car applications.
    We offer:
    • Ruggedized Polycarbonate Lens (NFPA 130 compliant)
    • Reverse polarity and transient spike protection
    • Screw or ¼” disconnect terminations
    • 25,000 hr minimum continuous operation
    • Compliance with CFR 49 part 221
    • 24-month warranty on LED fixtures
    All fixtures as a system meet or exceed these standards:
    • CFR 49 part 221
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards

  • LED Platform Light II

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

  • LED Platform Lighting

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

  • LED Platform/Ladder Access Lighting

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

    We supply:

    • Ruggedized polycarbonate lens (NFPA 130 compliant)
    • 20-90vdc & 50 – 130vdc operating range from the DC power supply through TDG’s Universal Driver
    • Robust machined and sealed aluminum housing ready for painting or anodizing to natural or black
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • 49CFR Part 38.81
    • EN 13272
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1

    NFPA 130:2010 Flame Smoke and Toxicity Standards

  • Side Indicator Lighting

    ,

    LED side indicator lights come in a variety of styles and position numbers.

    We offer:

    A commuter rail version visible to a distance of ¼ mile which accommodates long train sets
    Delphi Weather Pack connector as well as other sealed connectors upon request
    Modular versions intended for adjacent custom configuration placements
    Ruggedized machined solid aluminum housing ready for painting or for anodizing to natural or black
    Standardized LED internal drivers and LED modules that enable final housing configurations to be easily customized
    Ability for maintenance to be done from exterior or interior of the vehicle
    Optional flush lens for improved cleaning of the lens surface during car washing
    Reverse polarity and transient spike protection
    100,000-hr minimum continuous operation for an LED system
    24-month warranty on LED fixtures
    All fixtures as a system meet or exceed these standards:

    APTA Normal Lighting Standard RP-E-012-99
    APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    APTA Insulation Integrity Standard SS-E-001-98
    APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    NFPA 130:2010 Flame Smoke and Toxicity Standards

    Click for diagramatic Exterior Red/Amber Indicator Lights spec sheet.