Locomotive

  • LED Ditch Lights

    ,

    Long-lasting LED components designed to withstand shock & vibration to provide years of maintenance-free service.

    We offer:

    • 75W of power used at maximum setting including lens heating element
    • 30,000 hr service life
    • Beam pattern meets FRA requirements
    • Replacement for standard PAR56 sealed beam headlights and ditchlights
    • Light recognizes low/medium/high settings used. on existing locomotives
    • Integrated heating element prevents ice & snow to maintain unobstructed light output

    All fixtures as a system meet or exceed these standards:

    • FRA Certified
    • Sealed to IP67
    • CFR 49 Part 229.125 (a) (b) (d)
  • Cabinet Lighting

    ,

    High-powered LEDs replace 100-watt incandescent bulbs, and consume a much lower 24 watts. This lighting is intended for placement within cabinets or other areas such as vestibule/entry or washroom areas. The translucent lens ensures comfortable light levels without any harsh glare.

    We supply:

    • Single voltage (37.5 or 74vdc) versions, or dual function 74vdc/120vac versions which switch input voltage operation automatically
    • Ruggedized polycarbonate lens (NFPA 130 compliant) or glass lenses
    • Aluminum housing ready for painting or for anodizing to natural or black
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Cab Reading Lights

    ,

    The high-powered LED produces 300 LUX @ 36” with 360º adjustability. This ensures that
    light is cast onto the work surface, not onto the windshield or side glass.

    We offer:

    20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    A dimmer control version in which the dimmer can be placed remotely
    Several flange sizes or configurations
    Black powder-coated painted finish
    Reverse polarity and transient spike protection
    100,000-hr minimum continuous operation for an LED system
    24-month warranty on LED fixtures
    All fixtures as a system meet or exceed these safety standards:

    APTA Normal Lighting Standard RP-E-012-99
    APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    APTA Insulation Integrity Standard SS-E-001-98
    APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    NFPA 130:2010 Flame Smoke and Toxicity Standards

  • LED Number Board Lighting

    ,

    Install new LED fixtures or replace LED inserts easily in existing incandescent or fluorescent enclosures.

    We offer:

    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Simple terminal block connections or cable assembly connections
    • Various intensities available
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Task Lighting (Flood and Dome)

    ,

    This serves as a drop-in replacement for EMD pn 9096838 or MPI pn 1041198. The high-powered LED produces ~500 LUX @ 30” without casting light on windshield or side glass.

    We offer:

    20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    An illuminated switch or remote switch location options
    White or black powder coated painted finishes
    Reverse polarity and transient spike protection
    100,000-hr minimum continuous operation for an LED system
    24-month warranty on LED fixtures
    All fixtures as a system meet or exceed these safety standards:

    APTA Normal Lighting Standard RP-E-012-99
    APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    APTA Insulation Integrity Standard SS-E-001-98
    APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    NFPA 130:2010 Flame Smoke and Toxicity Standards

  • LED PAR 56 Locomotive / Auxiliary Headlight

    ,

    Long-lasting LED components designed to withstand shock & vibration to provide years of maintenance-free service.

    We offer:

    • 75W of power used at maximum setting including lens heating element
    • Beam pattern meets FRA requirements
    • Replacement for standard PAR56 sealed beam headlights and ditchlights
    • Light recognizes low/medium/high or low/high settings used. on existing locomotives
    • Integrated heating element prevents ice & snow to maintain unobstructed light output
    • Can be designed to work with existing outage detectors
    • Engineered by JW SPEAKER

    All fixtures as a system meet or exceed these standards:

    • FRA Certified
    • Sealed to IP67
    • CFR 49 Part 229.125 (a) (b) (d)

    View Spec Sheet here

  • Step Walkway Lighting

    ,

    This sealed LED walkway lighting insert is a drop-in replacement for standard step lights, and fits into existing mounting bases. Alternately, existing mounting bases will accept an optional TDG mounting base drop-in. Different conduit sizes available,

    We supply:

    • High-powered LEDs generating twice the light levels of standard 50-watt incandescent bulbs
    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Produces over 28 lux at 66” height
    • Simple terminal block connections at rear
    • Durable annodized finish
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • PAR46 Marker Lights

    ,

    This is a PAR46 drop-in replacement for sealed beam lights in both locomotive and cab car applications.

    We offer:

    • Ruggedized Polycarbonate Lens (NFPA 130 compliant)
    • Reverse polarity and transient spike protection
    • 20-95 vdc operation range
    • Screw or ¼” disconnect terminations
    • 25,000 hr minimum continuous operation
    • Compliance with CFR 49 part 221
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • CFR 49 part 221 compliance (test report available upon request)
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Reading Light

    ,

    The high-powered LED produces 300 LUX @ 36” with 360º adjustability. This ensures that
    light is cast onto the work surface, not onto the windshield or side glass.

    We offer:

    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Produces 379 lux at 36” and 300 Lux Intensity at 30”
    • A dimmer control can be mounted on flange or remotely
    • ‘Night Vision’ mode version available
    • Several flange sizes or configurations
    • Black powder-coated painted finish
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these safety standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Ladder Access Lighting

    ,

    These high-powered white LEDs provide bright illumination to platforms, walkways or ladder rungs without harsh glare to passing trains.

    We supply:

    • Ruggedized polycarbonate lens (NFPA 130 compliant)
    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Robust machined and sealed aluminum housing ready for painting or anodizing to natural or black
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • LED Stairway Lighting

    ,

    Clients may choose not only a single function version, but also a dual version which adds emergency system functionality.

    We offer:

    • Several sizes and styles
    • Ruggedized Polycarbonate Lenses (NFPA 130 compliant) which can be clear, translucent, or diffused
    • A variety of bezel materials (such as aluminum and Kydex) in many colors and finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these safety standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Red LED Night Vision Lighting

    ,

    Sealed LED units can be supplied with either dedicated red LED inserts, or dual function units. The dual function units add a normal or white LED setting for general lighting needs.

    We supply:

    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Simple terminal block connections at rear
    • A variety of flange & housing shapes
    • Several finish and color choices
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • APTA Normal Lighting Standard RP-E-012-99
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1

    NFPA 130:2010 Flame Smoke and Toxicity Standards

  • Engine Room Lights

    ,

    This is available in single voltage (37.5 or 74vdc) and dual function 74vdc/120vac versions. The dual version automatically switches dependent on input voltage type.

    We supply:

    • High-powered LEDs which consume just 24 watts but provides output of a 100-watt incandescent bulb
    • Ruggedized glass lens with cage
    • 80°C ambient temperature operation
    • Black powder-coated painted finish as standard, and other finishes available
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards
  • Main and Emergency Lights

    ,

    This high-powered LED for locomotives is a drop-in replacement for standard T12 fluorescent fixtures. It can also replace a 100-watt incandescent bulb, consuming just 24 watts in its place.

    We offer:

    • Optional self-contained Capacitive Storage Emergency Power system with 2 x 360º LED ‘Eyeball’ spotlights for a customizable 90 minutes of emergency lighting
    • 20-95vdc operating range from the DC power supply through TDG’s Universal Driver
    • Capacitors rated for 5 – 10 years of functional discharge service life (depending on Model & Environment)
    • Ruggedized polycarbonate lens (NFPA 130 compliant)
    • Black or Natural anodized finishes
    • Reverse polarity and transient spike protection
    • 100,000-hr minimum continuous operation for an LED system
    • 24-month warranty on LED fixtures

    All fixtures as a system meet or exceed these standards:

    • AAR S-580 Locomotive Crashworthiness Standard
    • Will help locomotive meet 49 CFR 229.127 (b) requirements
    • APTA Emergency Lighting Standard SS-E-013-99 Rev 1
    • APTA Insulation Integrity Standard SS-E-001-98
    • APTA Attachment Strength Standard SS-C&S-006-98 Rev 1
    • NFPA 130:2010 Flame Smoke and Toxicity Standards